Batch Print Reports

Generic features Manual

With Batch print (available from AVIX 4.7.11), you can print a hierarchy of reports to a specified path.These are the available reports: In the next dialog, by pressing browse, you can select the path to where the reports are saved. This is a method tree...

Filters

Generic features Manual

Filters make it easy to find what you are looking for.Don’t spend time scrolling through your data, use the filters instead. There are filters available for the balance tree, SMED tree, DFX tree, ergo tree, FMEA editor, method tree, parts, tools, and processe...

Approval Status

Enterprise Manual

This is only available in the "Enterprise" license is active in AVIX In order to be able to see and edit the approval status, this functionality must be switched on in the preferences. The icon decoration colors match the tasks given names. You can set all ...

How to add Pictures / Documents

Method Manual Work instructions & reports

Select level to add picture/document. Select additional tab. Choose to link or add document/picture/markup. To add a link to a document means to store the path to that document. If you move that document, the link will point to an empty location and...

Editing Added Pictures

Method Manual Work instructions & reports

In the additional tab, all pictures/documents can be handled.They can be deleted or re-arranged in order (used by some reports). Right clicking a picture makes is possible to edit it by adding arrows and text as a layer without changing the actual picture.The...

Creating Work Instructions

Method Manual Work instructions & reports

In AVIX there is a variety of different standard work instruction templates that can be used to print work instructions based on the data created in AVIX. Here we describe the output available from AVIX Method. To see what is and what is not printed, see chap...

Text Formatting in Work Instructions

Generic features Manual

From AVIX 4.6.3 it is possible to make text formatting of all input in AVIX. This can e.g. be the “Description field” used for adding an extra comment to the detailed word instruction. Every text input in AVIX that is used to generate output has this function...

Generating Data Output / Reports

Method Manual Work instructions & reports

AVIX also comes with a variety of standard data reports that can be generated in order to summarize and export the data in the analysis. Just as the work instructions, the reports are generated by selecting a level in the Method tree, and then pressing the pr...

Using Processes in AVIX

Method Manual Process library

Watch video: Process library The traditional way of working with AVIX is to create the data material in the Method tree. With this approach, one could say that the processes are owned by the station where they are performed and there isn't any common ...

Error Reporting

Generic features Manual

Sometimes problems occur in AVIX. It can be bugs of different types or system and hardware errors In AVIX (from version 4.6.9) it is possible to send a support issue directly to our support team that contains log files useful for their troubleshooting.Click t...

Icon / Label Decoration

Generic features Manual

Icon/label decorations can be turned on or off in the preferences: Icon/label decorations can appear in the 4 corners of the icon and have the following meaning: Task has an attached document/image/link. This can be turned on/off in the preferences by chec...

FAQ

Generic features Manual

I want to add a video, but I cannot find where to do this Create a Process TaskIn the Process Task editor, click and select a video Where is video? Method is always in the top right-hand corner if you click on I have closed a tab/a tree/something else and...

Introduction

Method Manual AVIX standard time theory

AVIX is an interactive improvement analysis system for all branches that include manual labor. The system uses video techniques, standard times and 12 different activities. Time is presented as productive, semi-productive or loss in a final analysis. Working w...

Productivity & Standard Times

Method Manual AVIX standard time theory

Productivity Productivity is what a person can achieve with material, capital and technology. Productivity is primarily a personal attitude. It is an attitude that favors progress; that makes one continually strive to improve that which already exists. It is ...

Color System

Method Manual AVIX standard time theory

In order to find improvements in a smart manner, AVIX uses a color system ofclassification. The different work operations required to perform a particular productionprocedure are classified according to three different color categories. With the help of the c...

Activities In AVIX

Method Manual AVIX standard time theory

All executed work operations are classed into different activities in AVIX. This enables the result to be calculated for each activity, that is, to see how the total time for the product is distributed between different activities. It is also the activities in...

Objects and Production aid

Method Manual AVIX standard time theory

In the AviX analysis system all components are classed as value objects or fixation objects. The degree to which productivity is affected depends on the type of object that is handled. Value objects have a fundamental function in the final product. This means ...

Setting Standard Times to Work Operations

Method Manual AVIX standard time theory

Standard Times A standard time is allotted to the object, based upon the distance that the object or production aid is moved and the difficulty in moving/handling the object or production aid. AVIX consists of four standard classes: Standard Class Eq...

Setting Standard Times to Movements

Method Manual AVIX standard time theory

When an operator cannot carry out a specific task within arms’ length, the operator must move. A standing operator has a reach of about 70 cm. When something is outside this reach, a movement must occur. These movements do not add any value to the product, but...

AVIX FMEA

FMEA Manual